DOLPHIN PRODUCT LINE

For Transcranial Doppler

Select the model that best meets your needs!

The next generation Transcranial Doppler (TCD) standalone system that will exceed everything you know and expect from a TCD system.

The most advanced cost-effective Transcranial Doppler (TCD) module, with identical performance and features to the Dolphin/4D.

DOLPHIN APPLICATIONS FOR TRANSCRANIAL DOPPLER

The DOLPHIN supports numerous standard and new unique features for the benefit of the medical staff and patients alike!

VASOSPASM AND
SAH

ARTERIOVENOUS
MALFORMATION

EVALUATION OF
ICP CHANGES

INTRACRANIAL
STENOSIS

VMR AND
AUTOREGULATION

BREATH
HOLDING

MONITORING

EMBOLI
DETECTION

PATENT FORAMEN
OVALE (PFO)

COLLATERAL
CAPACITY

BRAIN
DEATH

SICKLE CELL
DISEASE

SELECTED DOLPHIN FEATURES

The DOLPHIN supports numerous standard and new unique features for the benefit of the medical staff and patients alike!

System Features

High Quality Doppler




  • Fully digital Doppler processing



  • High resolution color M Mode



  • Visual and audio Replay at any depth!

Arrow
Arrow
Slider

Wide Probes Selection




  • 1.6 Mhz, 2 MHz, 4 MHz and 8 MHz probes



  • Bialteral



  • Intraoperative

Improved Workflow




  • Flexible design according to your needs!



  • User friendly interface designed for touch screen



  • All standard TCD features and much more!

Advanced Features




  • Offline Post Processing of depth, sample volume, gain, scale and filter



  • Multi Depth



  • Velocity Profile

Monitoring and HITS Detection

Advanced HITS Detection




  • Proprietary HITS Algorithm with accurate ranking



  • Detection of direction, energy, duration and depth



  • Option to detect HITS in all gates!

Continuous Monitoring




  • Comfortable Headset



  • Replay of entire Doppler spectrum and audio



  • Parameters trends graph



  • Alerts, automatic & predefined markers

HITS Analysis




  • Fast and thorough review of all HITS



  • Special display up to 50 times faster than spectrum!



  • HITS and artifacts distribution charts



  • Complex & Energy graphs

Specialty Tests

Dedicated Vasospasm Protocol




  • Configurable thresholds



  • Special report layout with trends



  • On screen trends for easier tracking

Dedicated PFO Protocol




  • Advanced analysis of shower events



  • Entire measurement spectrum display



  • Special report layout

Dedicated Sickle Cell Protocol




  • Protocol according to STOP procedure



  • Configurable thresholds



  • Special report layout with trends

Autoregulation Protocols




  • Breath Holding



  • VMR with Capnograph



  • VMR without Capnograph



  • Special report layout for each protocol

Ease of Use

One Key Operation




  • Easily operate the system with one main key



  • Remain focused on the patient



  • Key function automatically adapts to current protocol



  • Use from touch screen, remote, foot switch, mouse or keyboard.

Interactive Screens




  • Large user-friendly touch-screen display



  • Everything on screen is interactive



  • Configurable screen display

Remote Control and Foot Switch




  • Easy to use wireless remote control



  • Keep your focus on the patient with a dedicated foot switch



  • Configurable buttons on remote and foot switch according required functions
Arrow
Arrow
Slider

Language Support




  • Dolphin operation in your native language



  • Ensures optimal operation

Flexibility

Flexible Protocols




  • Easily configurable protocols



  • Support of unlimited number of protocols



  • Very friendly protocol editing!

Arrow
Arrow
Slider

Configurable Reports




  • Design your own report display



  • Customized hospital/clinic logo and details



  • Unlimited configuration of report templates

Analysis and Research Options

Export Data




  • Export to popular formats such as PDF, Excel, Word, JPEG and more



  • Export entire examinations



  • Research oriented exports such as Video clips, Matlab and raw data

Statistical Analysis




  • Built in statistics tool



  • Informative pie charts and advanced parameters comparison



  • Export statistical data to Excel

Networking (DICOM/HL7/GDT) and Review Station

Network Connectivity




  • Easily configure connectivity with automated connection test



  • DICOM Worklist, Storage and Structured Report



  • HL7 Query, ADT, Orders and Reports



  • GDT Interface

Unlimited Review Stations




  • Unlimited number of review stations



  • Replay examinations with full spectrum and Doppler audio



  • Complete shared network database solution



  • Reanalyze and add interpretations to a finalized report

MORE ABOUT THE DOLPHIN

Upgrade your Old Sonara!

DOLPHIN VS. SONARA COMPARISON

The Dolphin systems are the  ideal upgrade to the now obsolete Sonara systems, which used to be the vascular market leader for many years.

You will find many of the known features and options of the Sonara available in the advanced and modern Dolphin user interface, plus many more options that are designed to support routine and advanced clinical examinations around the world.

Option or Feature Sonara Dolphin/4D
Technology Partially analog Advanced, Fully digital
Data Processing Completely flexible, available for offline post-processing
Weight 10 Kg 6 kg
Display size 15” Square 18” Wide Screen
Touch Screen Resistive Multi Touch Capacitive
1.6 Transcranial probe
Intraoperative probe * Not for USA and Canada
Cybersecurity protections
External channels
Camera support
Wireless remote control
Capnograph support
Full HD Resolution Support
4D Replay along ultrasound beam
Shared Database solution for unlimited review stations
DICOM Structured Reporting
Post processing of Depth, sound, gain, sample, scale and filter
Multi Depth with parameters and envelope
PFO Protocol
Sickle Cell Protocol
Cognitive Response
Vasospasm Protocol
Waveform Labels (manual and automatic)
Unlimited configurable protocols
Advanced free text report editor
Advanced data backup options
Configurable user profile settings
Advanced HITS Analysis display
Customized Patient Details Page
Dedicated and separately configurable print layouts for each type of test
Advanced search
Quick review of previous exams

Additional Reading

SVU Professional Performance Guidelines

Intracranial Cerebrovascular Evaluation Transcranial Doppler (Non-Imaging) and Transcranial Duplex Imaging (TCD-I)

Read Article...


Assessment: Transcranial Doppler Ultrasonography

Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology

Read Article...


Transcranial Doppler Assessment of Cerebral Autoregulation

Bellapart J, Fraser JF.

Read Article...


Transcranial doppler ultrasonography should it be the first choice for persistent foramen ovale screening?

Monika Komar, Maria Olszowska, Tadeusz Przewłocki, Jakub Podolec, Jakub Stępniewski, Bartosz Sobień, Rafał Badacz, Anna Kabłak-Ziembicka, Lidia Tomkiewicz-Pająk and Piotr Podolec

Read Article...


Ultrasound Assessment of the Intracranial Arteries

DARIUS G. NABAVI, MD; MARTIN A. RITTER, MD; SHIRLEY M. OTIS, MD; and E. BERND RINGELSTEIN, MD

Read Article...


Monitoring of Cerebral Autoregulation

Marek Czosnyka, Chad Miller
The Participants in the International Multidisciplinary Consensus Conference on Multimodality Monitoring

Read Article...


Evidence-based guideline update: Determining brain death in adults

Report of the Quality Standards Subcommittee of the American Academy of Neurology
Eelco F.M. Wijdicks, Panayiotis N. Varelas, Gary S. Gronseth and David M. Greer

Read Article...


Evidence-Based Management of Sickle Cell Disease

Expert Panel Report, 2014
U.S. Department of Health and Human Services

Read Article...


Stroke Prevention Trial in Sickle Cell Anemia (STOP): extended follow-up and final results

Margaret T. Lee, Sergio Piomelli, Suzanne Granger, Scott T. Miller, Shannon Harkness, Donald J. Brambilla, Robert J. Adams, and for the STOP Study Investigators

Read Article...

VASOSPASM AND SAH

Cerebral Vasospasm is typically the outcome of Subarachnoid Hemorrhage (SAH) as a result of an aneurysm rupture. Early detection of vasospasm is critical since it allows timely intervention.

TCD is rather specific for this condition, and allows non-invasive, continuous bed-side monitoring.  Vasospasm is characterized by increased velocities due to arterial narrowing. Severe vasospasm is defined in various international guidelines, and typically when mean velocities exceed 200 cm/sec, moderate conditions are with mean velocities between 120-200 cm/sec, and mild vasospasm is for mean velocities near 120 cm/sec. Additionally, velocities in the middle cerebral artery can be compared to internal carotid artery velocities, and the resulting ratio (Lindergaard index) can indicate cerebral vasospasm when it is greater than 3.

Typically, vasospasm is a developing pathology, and requires day by day monitoring of blood flow velocity values.  The Viasonix Dolphin system provides a dedicated vasospasm protocol that allows setting velocity thresholds for immediate identification of the severity of the vasospasm condition.  In addition, an immediate velocity trend analysis is provided in order to help identify the critical time whereby intracranial velocities are dramatically increased, and immediate clinical intervention is required.

The Dolphin also provides an ideal platform for the identification of the critical highest intracranial velocities.  All data is saved both in the time domain and at all depths along the ultrasound beam, which allows the examiner to review the data after freeze to explore the measured blood flow velocities.

ARTERIOVENOUS MALFORMATION

Arteriovenous Malformation (AVM) relates to a condition whereby the arterial flow bypasses the capillary circulation and connects directly to the venous drainage, thus not allowing for appropriate tissue perfusion.

This condition is characterized by low resistance to blood flow, resulting in high volume flow rates. AVM is therefore characterized by high mean velocities – although lower then with severe vasospasm – which are coupled with a low pulsatility index (PI).

The Viasonix Dolphin multi-depth options allows to simultaneously view and measure the blood flow spectrum at different depths along the beam and quickly identify deviations from expected waveform patterns.

EVALUATION OF ICP CHANGES

Intracranial pressure (ICP) is the pressure inside the skull and thus in the brain tissue and cerebrospinal fluid. Elevated ICP has a direct effect on the cerebral blood flow velocity and its’ pulsatility, which can be detected with simple transcranial Doppler (TCD) measurements.

The Viasonix Dolphin has the ability for multi-parameter analysis which allows close evaluation of cerebral condition. In addition, dedicated trend analysis displays help to closely monitor changes in cerebral condition for timely identification of deterioration of cerebral perfusion.

INTRACRANIAL STENOSIS

Intracranial stenosis relates to a focal narrowing of the artery, either as a result of an atherosclerotic lesion or as a result of external compression due to a tumor.

TCD will easily identify a local increase in blood flow velocities, characterized by the fact that proximal or distal to the stenosis the velocities will be much lower that at the site of lesion itself. Peak focal velocities above 150 cm/sec can indicate an arterial stenosis. However, if the severity of the stenosis is beyond its' critical level, velocity signals may be diminished.

The Viasonix Dolphin ideally allows multi-depth scanning along the ultrasound beam, and display in both the m-mode and spectral domains. This allows for simultaneous analysis and evaluation of pre- and post-stenotic flows as well as in the focal region of the stenosis itself.

VMR AND AUTOREGULATION

Vasomotor reactivity (VMR) and autoregulation define the physiological compensatory mechanisms when flow is impaired. Identification of exhausted VMR can be a good indication for high risk for stroke. VMR can be assessed with TCD under two specific conditions: hypercapnia or CO2 reactivity, and with intravenous injections of Acetazolamide or the Diamox test. Note that the Diamox test is not accepted in some countries.

Typically, an increase in peak velocities above 40% during induced increase in CO2 reflects intact VMR, whereas a smaller increase reflects different degrees of impaired VMR. Absence of flow increase reflects a complete exhaustion of the autoregulatory capacity.

The Viasonix Dolphin is ideally set with dedicated Unilateral and Bilateral protocols to determine the autoregulatory capacity of the cerebral circulation of the patient. Doppler waveforms are captured automatically during baseline, and peak (hypercapnia) and minimal (hypocapnia) flows for immediate evaluation, as well as a display of the blood flow fluctuations during entire test process. The respective parameters are automatically shown in a dedicated table with the VMR index readily displayed.

BREATH HOLDING

The Breath Holding (BH) test is a specific test for evaluation of Vasomotor Reactivity (VMR) and cerebral autoregulatory capacity.

Identification of exhausted VMR can be a good indication for high risk for stroke. Breath holding induces and increase in CO2, which in turn results in cerebral vasodilation. An increase in peak velocities during breath holding indicates different levels of patent autoregulatory capacity, While the absence of flow increase during the BH test indicates diminished physiological vasodilatory capacity and potentially high risk for stroke.

The Viasonix Dolphin is ideal for BH test with a dedicated breath holding protocol. This protocol leads the examiner with the different stages of the test, and provides automatically the breath holding index (BHI) for clinical determination.

A large timer displayed during the test helps both the patient and the examiner in keeping track of the duration of the procedure. Automatically placed markers identify the peak and minimal velocities measured during the procedure.

MONITORING

Cerebral monitoring can be critical for identification of neurological complications. Relative and/or sudden changes in cerebral blood flow velocities can become a powerful diagnostic tool and effect the immediate clinical intervention.

Bilateral cerebral monitoring is particularly useful during cardiac surgery for identification of embolic events, which may be the source of post-surgery neurological deficiencies.

The Viasonix Dolphin supports both unilateral and bilateral cerebral blood flow monitoring with a dedicated and easy to use monitoring headset. A variety of monitoring tools allow to view the complete duration of the monitored procedure, as well as zoom in or out on specific regions of interest. A variety of automatically inserted event markers, as well as user defined markers, help in post-monitoring analysis.

In addition, the Dolphin supports the display of data obtained from external channels for close correlation with the cerebral blood flow information.

EMBOLI DETECTION

Cerebral emboli can take the form of atherosclerotic plaques, air bubbles or blood clots. The immediate risk of cerebral embolization is in impaired perfusion which may lead to stroke and death.

TCD can detect the embolic signals in the blood flow velocity waveforms, which are characterized by high intensity, short duration and unidirectional signals. High intensity transient signals (HITS) are often considered as embolic events.

The Viasonix Dolphin has the most advanced HITS detection and analysis platform. Dedicated screens show the specific embolic characteristics, such as its’ energy, velocity and duration patterns, as well as display its’ travel route in the time and depth domains.

Furthermore, the Dolphin can detect embolic events that are even not within the measured spectrum of the central depth, due to its’ powerful multi-range and multi-depth analysis capabilities.

PATENT FORAMEN OVALE (PFO)

Transcranial Doppler is very useful in the identification of patent foramen ovale (PFO). PFO is a hole between the left and right atriums of the heart. While this hole exists in everyone before birth, it most often closes shortly after birth. If the hole fails to close naturally after birth it is called PFO.

TCD can easily identify the existence of PFO by injecting micro-bubbles (air mixed saline) to the patient vein (typically the antecubital vein), while the Doppler signal is recorded during the Valsalva maneuver. If embolic events are found in the recorded cerebral blood flow, typically the middle cerebral artery (MCA), then this is an indication of the existence of PFO in the patient.

The Viasonix Dolphin is ideal for PFO examinations, with a dedicated PFO protocol. The test can be performed unilaterally or bilaterally, with automatic count of high intensity transient signals (HITS) which are considered as embolic events. Each embolic event can be further analyzed with extremely high temporal and depth resolutions, and the specifications of each event displayed in a special screen. Furthermore, the embolic travel in the depth and time domains can be viewed for additional discrimination from artifact events.

COLLATERAL CAPACITY

Similar to cerebral autoregulation and vasomotor reactivity, cerebral collateral flow reflects an alternative compensatory mechanism to pathological flow conditions. The cerebral collateral pathways include side-to-side via the anterior communicating artery, posterior-to anterior via the posterior communicating artery, and external-to-internal via the ophthalmic artery. TCD can detect reverse velocities in the collaterally perfused arteries, indicating the viability or absence of this compensatory mechanism.

The Viasonix Dolphin’s highly sensitive M-mode display identifies forward or reversed blood flow, throughout the depth range, for analysis of this brain protection mechanism.

BRAIN DEATH

Brain Death condition reflects an extensive and irreversible brain damage, characterized by almost no volume blood flow to the brain. Timely identification of brain death is important in cases of organ donations.

TCD can detect the different stages of brain death through analysis of the particular waveforms: a sharp systolic peak followed by near zero diastolic velocities; systolic spikes followed by retrograde diastolic velocities; short spikes; and ultimately, no signals at all. Note that there are countries in which the use of TCD for diagnosis of brain death is not accepted. For determination of brain death, the characteristic waveforms should be displayed in all intracranial vessels. In order to accept the absence of a Doppler signal in any vessel, a prior valid measurement must be identified in the same vessel to ensure that the access temporal window is fine.

The Viasonix Dolphin special m-mode option allows the examiner to view flows at all depths along the ultrasound beam. Thus, even after the measurement is freezed the examiner can scroll back and view signals from any depth and replay the spectrum from any depth, even if it is different than the original set depth. This significantly reduces the risk of missing a valid blood flow signal and reaching an erroneous clinical diagnosis.

SICKLE CELL DISEASE

Sickle cell disease is a disorder of the blood caused by abnormal hemoglobin which causes distorted (sickled) red blood cells. It is associated with a high risk of stroke, particularly in the early years of childhood.

Transcranial Doppler (TCD) can be significant in the prevention of stroke under this condition. Mean of maximum cerebral velocity readings are obtained, and results are classified as normal, conditional, abnormal or inadequate based on the measurements. Clinical treatment based on the findings can be significant in stroke prevention.

The Viasonix Dolphin is ideal for sickle cell disease diagnosis and monitoring, with a dedicated sickle cell protocol. Special markers, which can also be configured by the examiner, clearly mark the velocity thresholds according to international guidelines, help in the identification and documentation of the pathology.